Multi-Purpose Reusable Respirator

Multi-Purpose Reusable Respirator
Product Introduction:
The Multi-Purpose Reusable Respirator is a dual-filter elastomeric half-mask engineered to accommodate interchangeable bayonet-mount chemical cartridges and particulate filters for industrial respiratory protection.
Send Inquiry
Description
Technical Parameters

The Multi-Purpose Reusable Respirator is a dual-filter elastomeric half-mask engineered to accommodate interchangeable bayonet-mount chemical cartridges and particulate filters for industrial respiratory protection. Molded from medical-grade thermoplastic elastomer, this facepiece maintains structural stability and seal compliance across hazardous operating environments.

 

Key Features

01/

Universal Bayonet Interface
Twin-bayonet connection ports designed to lock compatible filter cartridges securely with an audible tactile click.

02/

Dual Inhalation Valves
Low-resistance silicone valve diaphragms configured to reduce inhalation effort and limit moisture accumulation during extended shifts.

03/

Contoured Face Seal
Engineered edge geometry designed to conform to diverse facial profiles and maintain airtight integrity under movement.

04/

4-Point Head Harness
Adjustable woven strap assembly connected to a rigid crown cradle to distribute tension evenly across the head.

05/

Downward Exhalation Vent
Directs exhaled breath downward to prevent fogging when worn in combination with safety glasses or face shields.

Design & Components

Facepiece Body

Medical-grade Thermoplastic Elastomer (TPE) resistant to industrial cleaning agents and facial oils.

Valve Diaphragms

High-flexibility silicone material providing rapid response to breath cycles.

Bayonet Lugs

Rigid molded side-ports engineered for repetitive filter attachment and detachment cycles.

Harness Assembly

High-elasticity polyester straps paired with a durable polypropylene crown distribution plate.

Pre-Filter Retainer

Snap-fit polypropylene covers designed to hold particulate filter pads over gas cartridges.

 

Technical Specifications

 

Parameter

Specification

Standard Reference

Respirator Type

Twin-Filter Half Mask

EN 140:1998

Body Material

Hypoallergenic TPE

ISO 10993 Biocompatibility

Connection System

Dual-Bayonet Mount

Standard Bayonet Interface

Inward Leakage Rate

Less than 1.5%

EN 140 Test Method

Inhalation Resistance (30 L/min)

40 Pa

EN 140 Clause 7.12

Inhalation Resistance (95 L/min)

120 Pa

EN 140 Clause 7.12

Exhalation Resistance (160 L/min)

180 Pa

EN 140 Clause 7.12

Weight (Without Filters)

125 g

Laboratory Scale

Operating Temperature

-10°C to +55°C

Climate Chamber Testing

Shelf Life

5 Years

Sealed Original Packaging

 

Applications & Limitations

Recommended Applications

  • Chemical Handling: Protection against organic vapors, solvents, and liquid mists during fluid transfer and vessel maintenance.
  • Surface Coating: Spray painting, lacquer application, and epoxy resin processing operations.
  • Metal Fabrication: Welding, cutting, and grinding processes generating combined metal fumes and dust.
  • General Construction: Masonry cutting, sanding, and insulation handling operations.
  •  

Usage Limitations

  • Not for use in atmospheres containing less than 19.5% oxygen.
  • Not for use in environments immediately dangerous to life or health.
  • Do not use when facial hair crosses the sealing edge of the facepiece.
 

 

Compatible Filters & Accessories

 

Organic Vapor Cartridges: Absorbs organic gases and vapors with boiling points above 65°C.
Combination Gas & Particulate Canisters: Filters mixed exposures of acid gases, organic vapors, and solid aerosols.
Particulate Disc Filters: High-efficiency electrostatic media for fine dust, welding fumes, and mists.
Particulate Pre-Filter Pads: Disposable filter pads mounted onto chemical cartridges to capture coarse dust.
Snap-On Retainers: Polypropylene caps securing pre-filter pads onto gas cartridges.

 

Use & Maintenance

 

Pre-Use Seal Inspection

  • Positive Pressure Check: Cover the exhalation valve cover with the palm of the hand and exhale gently. The facepiece should inflate slightly without air leaking past the edge seal.
  • Negative Pressure Check: Cover the filter inlets with hands, inhale gently, and hold breath for 10 seconds. The facepiece should collapse inward against the face.

Cleaning & Washing

  • Detach all filter cartridges before cleaning the mask body.
  • Immerse the elastomeric facepiece in warm water below 40°C mixed with a neutral detergent.
  • Rinse thoroughly with clean water and air-dry in a clean area away from direct sunlight.
 

Our Certificate

 

Manufacturing operations adhere to certified ISO 9001 Quality Management Systems, with production lots verified through routine laboratory testing to ensure compliance with applicable technical standards.

 

product-1-1

 

OEM/ODM & Supply Information

 

Customization Options

Custom Pantone color matching, laser-etched brand marking, custom box printing, and localized instruction inserts.

Minimum Order Quantity

500 units for standard configuration; 2,000 units for customized color or private labeling.

Packaging Configuration

1 unit per sealed polybag, 1 inner box per unit, 20 inner boxes per master shipping carton.

Carton Dimensions

58 cm × 38 cm × 32 cm

Carton Gross Weight

8.5 kg

Production Lead Time

20 to 25 days following sample approval and deposit receipt.

Quality Control Process

100% inline checking for valve seating and bayonet engagement; lot-by-lot pressure differential testing.

 

FAQ

 

Q: What filter connection structure is used on this mask?

A: This model utilizes a standard dual-bayonet connection mechanism compatible with standardized bayonet-style chemical cartridges and particulate filters.

Q: How should buyers select the correct filter combination for specific industrial hazards?

A: Filter selection depends on the airborne contaminant profile. Organic vapors require gas cartridges, dust and fumes require particulate filters, and mixed hazards require combination cartridges.

Q: Can the elastomeric facepiece withstand regular detergent cleaning?

A: Yes, the TPE body maintains structural flexibility and seal performance after cleaning with warm water and neutral detergents or standard sanitizing wipes.

Q: What is the replacement interval for the mask body and valve components?

A: The main facepiece body maintains mechanical performance for 3 to 5 years under proper storage. Silicone valve diaphragms should be inspected daily and replaced annually or when damaged.

Q: What custom packaging options are available for volume distributor orders?

A: Volume orders support private label printing on inner boxes, custom master carton marking, localized instruction sheets, and laser-engraved logos on the head harness cradle.

 

Hot Tags: multi-purpose reusable respirator, China multi-purpose reusable respirator manufacturers, suppliers, factory, Bayonet Mount Respirator, Full Face Respirator for Laboratory Chemical Protection, Low Breathing Resistance Respirator, ODM Reusable Respirators, Organic Vapor Half Mask Respirator, Silicone Full Face Respirator

Send Inquiry
ZK-BEST(XIAMEN) ENVIRONMENT SCIENCE & TECHNOLOGY CO.,LTD
We are able to perform R&D for different customers with variant requirement.
contact us